· VORTA Team · Process Streams · 5 min read
Thinner fluids, better flow: VORTA for viscosity reduction
Excess viscosity can make process streams difficult to handle. Research using VORTA shows how vortex cavitation can change polymer solution flow, and why treatment should follow a practical viscosity target.
Thick fluids can be costly to pump, mix and treat. In food processing, viscosity affects pump performance. At a wastewater plant, sludge flow behaviour influences how equipment handles the material. Viscosity reduction is a practical concern wherever a stream has become too thick for the next process step. [2, 3]
The usual options have consequences of their own. Heating requires energy, dilution increases the volume to handle, and chemical additives must be compatible with the product and downstream treatment. A useful alternative needs to change how the fluid flows while keeping those wider process requirements in view.
Vortex cavitation offers another way to approach the problem. A study published in Fluids examined aqueous polyacrylamide solutions using a device supplied by VIVIRA, the company behind VORTA. The researchers reduced viscosity and elastic behaviour, with reductions observed both with and without added salts. Pumping supplied the treatment energy. [1]
The study provides a specific example of viscosity reduction without relying on heating or chemical addition. Its results support trials on polymer-bearing streams, with the treatment target and operating conditions chosen for the actual material and the job it needs to do.
Changing how a polymer solution flows
Polyacrylamide is used in applications including water treatment and oil recovery. Its long molecular chains affect how a solution flows. In the study, more concentrated solutions showed stronger shear thinning, meaning their apparent viscosity fell as the rate of deformation increased. Some solutions also showed elastic behaviour, tending to recover after deformation. [1]
Inside a VORTA device, swirling flow creates low pressure that allows tiny vapour cavities to form. As pressure recovers, the cavities collapse. The resulting local forces can break polymer chains and change the solution’s flow properties.
The researchers observed lower viscosity and an almost purely viscous response after treatment. They attributed these changes to shorter polymer chains and weaker interactions between them. Those molecular explanations are interpretations of the rheological measurements, rather than direct measurements of molecular weight in this study. [1]
For process development, that distinction matters. The measured change in flow behaviour is the starting point for a trial. The next question is whether that change helps the liquid perform as required in the actual process.
Knowing when to stop
The study found that viscosity reduction could reach a point of diminishing returns. For solutions without added salt, further treatment eventually produced little additional change. [1]
That suggests a useful approach to a process trial. Measure the response during treatment and look for the point where further treatment produces too little improvement to justify the extra time and energy. Each stream needs testing to establish how it responds. The target should be the viscosity needed for the next process step.
The water chemistry matters
The researchers found that dissolved salts affected both the initial apparent viscosity and the response to cavitation. With added salts, the treated solutions moved closer to Newtonian behaviour, where viscosity changes little with shear rate. Different salts had different effects on the initial elasticity. A lower viscosity therefore did not always mean less elasticity before cavitation treatment. [1]
The practical lesson is to test a representative liquid, including its dissolved salts. Results from a polymer dissolved in distilled water may not describe the same polymer in a process stream. The salt experiments help explain that sensitivity; they do not establish salt addition as the right treatment choice for another plant.
Testing against the job the fluid needs to do
Thinner is useful when excess viscosity is the problem. In an application that depends on the polymer’s thickening action, reducing it could make the fluid less effective. The treatment target has to follow the job the fluid needs to do.
A VORTA Labs trial can assess that target using the actual process stream. Useful measurements include viscosity under conditions relevant to the process, its response to treatment, and the energy used to reach the target. Where elasticity affects handling, it should be measured too.
The paper demonstrates viscosity control in laboratory polyacrylamide solutions. Pumping savings, increased throughput and downstream treatment performance would need separate measurements on the intended process. Lower viscosity alone also does not demonstrate complete polymer removal.
For a polymer-bearing stream that is difficult to handle, this research supports a specific next step. Test whether VORTA can reach the required flow properties, then establish the treatment level that achieves them without unnecessary recirculation.
Talk to VORTA Labs about a viscosity-control trial on your process stream.
[1] Fleite, S.N., Balbi, M.d.P., Ayude, M.A. and Cassanello, M. 2025. ‘Rheological Features of Aqueous Polymer Solutions Tailored by Hydrodynamic Cavitation’. Fluids 10, 169. Read the open-access paper.
[2] Jia, X., Chu, Q., Zhu, Z., Ding, Q. and Gao, P. 2022. ‘Influence of Fluid Food Viscosity on Internal Flow Characteristics of Conveying Pump’. Frontiers in Nutrition 9, 910589. Read the open-access paper.
[3] Baroutian, S., Eshtiaghi, N. and Gapes, D.J. 2013. ‘Rheology of a primary and secondary sewage sludge mixture: Dependency on temperature and solid concentration’. Bioresource Technology 140, 227-233. Read the paper.